15
Operating and Safety Instructions
Always disconnect the electric and power supply first before carrying out these
works.
If the machine is not active because of maintenance or service, put a warning
message that can be easily seen, indicating the situation
8.2. AIR PRESSURE ADJUSTMENT
8.2.1. Pull the adjustment button of the conditioner upwards
8.2.2. Turning the adjustment button in clockwise direction increases the
pressure.
8.2.3. Turning the adjustment button in counter clockwise direction decreases
the pressure.
8.2.4. Once you read 6-8 Bar on the manometer, push the adjustment button of
the conditioner down and lock it in that position.
8.2.5. To make up the lessen oil level in the oil tank, take out the oil depot by
turning. And re-fasten the oil depot after make up.
8.2.6. The manufacturer recommends to use the following oils with the
conditioner: TELLLUS C 10 / BP ENERGOL HLP 10/ MOBIL DTE LIGHT / PETROL
OFISI SPINDURA 10.
8.2.7. To discharge the accumulated water in the lubricator, loosen the water
discharge nut.
8.2.8 Adjust the lubricator working level to once for 10 cycles.